Working conditions
Identify temperature, contact fluids and repeated movement.

Custom manufacturing example · Custom silicone rubber eyelet wire harness grommets
CUSTOM RUBBER & SILICONE MANUFACTURING
A custom component for your assembly.
Define the mating surfaces, dimensions and working conditions. ETOL manufactures the part to the agreed design and material.
Share the part, its application and your estimated quantity.

Selected for the contact, temperature and movement
Define the visible surfaces and intended color
Develop holes, lips and walls around the mating parts
Match the attachment and installation method
Custom silicone rubber eyelet wire harness grommets protect the opening occupied by a bundled lead. A branch or junction near the entry should remain outside a bore intended for a consistent harness section, otherwise it can prevent the rubber from resting naturally around the bundle.
ETOL can vary dimensions, compound, hardness and color. Assess the harness in its finished wrapped form and identify the section that will remain inside the grommet after connection. Choose the mounting profile separately for the panel thickness and cutout.
Thread the bundle without allowing an individual lead to slip under the flange. Position the branch and nearby clips so they do not pull the entry to one side. Inspect the eyelet after the harness has been connected and secured. During repairs, revisit the fit if wrapping or a branch arrangement is changed. Keep the bore clear of debris and check the hidden lip where accessible. Replace damaged rubber before closing the assembly rather than leaving a tear concealed beneath the expanded bundle.
Photos illustrate structure or material only. Thread the bundle without allowing an individual lead to slip under the flange. ETOL directly manufactures custom-shaped silicone and rubber parts to your requirements.
FIND THE RIGHT FIT
Choose a profile to compare part numbers and dimensions. Inch and metric sizes are listed in separate tables.
274 entries for Type D round through-hole grommets. Original fractions are retained, and exactly equivalent standard inch fractions replace decimal values where possible. Other values remain decimal inches.
| P/N | ID (C) | GD (A) | OD (D) | GW (B) | T (E) | Unit |
|---|---|---|---|---|---|---|
| RG2001 | 7/64 | 5/32 | 1/4 | 3/32 | 11/64 | inch |
| RG2002 | 7/64 | 5/32 | 1/4 | 3/64 | 11/64 | inch |
| RG2003 | 5/32 | 7/32 | 9/32 | 3/32 | 7/32 | inch |
| RG2004 | 1/8 | 3/16 | 5/16 | 1/16 | 3/16 | inch |
| RG2005 | 9/64 | 1/4 | 5/16 | 5/64 | 1/4 | inch |
| RG2006 | 5/32 | 1/4 | 5/16 | 7/64 | 13/64 | inch |
| RG2007 | 1/8 | 3/16 | 11/32 | 1/16 | 7/32 | inch |
| RG2008 | 1/8 | 1/4 | 11/32 | 1/16 | 7/32 | inch |
| RG2009 | 1/8 | 1/4 | 11/32 | 3/32 | 1/4 | inch |
| RG2010 | 9/64 | 3/16 | 11/32 | 1/16 | 3/16 | inch |
| RG2011 | 3/16 | 9/32 | 13/32 | 3/32 | 5/16 | inch |
| RG2012 | 3/16 | 5/16 | 13/32 | 1/16 | 7/32 | inch |
| RG2013 | 3/16 | 9/32 | 7/16 | 3/32 | 7/32 | inch |
| RG2014 | 3/16 | 5/16 | 7/16 | 1/16 | 3/16 | inch |
| RG2015 | 3/16 | 5/16 | 7/16 | 1/4 | 3/8 | inch |
866 entries for round panel openings. Compare the outside diameter, inside diameter, panel hole, panel thickness and overall thickness for the required fit.
| P/N | OD | ID | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RG6-2-4-1 | 6 | 2 | 4 | 1 | 3 | mm |
| RG6-2-4-1.5 | 6 | 2 | 4 | 1.5 | 3.5 | mm |
| RG6-2-4-2 | 6 | 2 | 4 | 2 | 4 | mm |
| RG8-2-6-1 | 8 | 2 | 6 | 1 | 3.4 | mm |
| RG8-2-6-1.5 | 8 | 2 | 6 | 1.5 | 3.9 | mm |
| RG8-2-6-2 | 8 | 2 | 6 | 2 | 4.4 | mm |
| RG8-3-6-1 | 8 | 3 | 6 | 1 | 3.4 | mm |
| RG8-3-6-1.5 | 8 | 3 | 6 | 1.5 | 3.9 | mm |
| RG8-3-6-2 | 8 | 3 | 6 | 2 | 4.4 | mm |
| RG8-4-6-1 | 8 | 4 | 6 | 1 | 3.4 | mm |
| RG8-4-6-1.5 | 8 | 4 | 6 | 1.5 | 3.9 | mm |
| RG8-4-6-2 | 8 | 4 | 6 | 2 | 4.4 | mm |
| RG10-3-7-1 | 10 | 3 | 7 | 1 | 4 | mm |
| RG10-3-7-1.5 | 10 | 3 | 7 | 1.5 | 4.5 | mm |
| RG10-3-7-2 | 10 | 3 | 7 | 2 | 5 | mm |
98 GRA sizes with a flanged sleeve profile. Compare the inside diameter, groove diameter and sleeve dimensions.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| GRA5000 | 2 | 8 | 5 | 7 | 8.5 | mm |
| GRA5001 | 3 | 8 | 5 | 7 | 8.5 | mm |
| GRA5002 | 3.5 | 9 | 6 | 8 | 9.5 | mm |
| GRA5003 | 3.2 | 8.2 | 6 | 8 | 9 | mm |
| GRA5004 | 3.5 | 11 | 6.8 | 8 | 10 | mm |
| GRA5005 | 4 | 10 | 7 | 8 | 9.5 | mm |
| GRA5006 | 4 | 11.5 | 7.3 | 8 | 10 | mm |
| GRA5007 | 4.5 | 12 | 7.8 | 8 | 10 | mm |
| GRA5008 | 4.5 | 11 | 8 | 8 | 9.5 | mm |
| GRA5009 | 5.5 | 13 | 9 | 8 | 10 | mm |
| GRA5010 | 5 | 12.5 | 8.3 | 8 | 10 | mm |
| GRA5011 | 5 | 13 | 9 | 9 | 11 | mm |
| GRA5012 | 6 | 14 | 10 | 9 | 11 | mm |
| GRA5013 | 7 | 15 | 11 | 10 | 12 | mm |
| GRA5014 | 7.5 | 16 | 12 | 10 | 12 | mm |
47 RGB sizes with a retaining lip below the mounting groove. Check the groove width and overall thickness for the panel assembly.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RGB6001 | 2 | 8.5 | 4.6 | 3 | 8 | mm |
| RGB6002 | 2.5 | 9 | 5 | 3 | 7 | mm |
| RGB6003 | 3 | 9.5 | 5.5 | 3 | 7 | mm |
| RGB6004 | 3.5 | 10 | 6 | 4 | 8 | mm |
| RGB6005 | 4 | 10.5 | 6.5 | 4 | 8 | mm |
| RGB6006 | 4.5 | 11 | 7 | 4 | 8 | mm |
| RGB6007 | 5 | 11.5 | 7.5 | 4 | 8 | mm |
| RGB6008 | 5.5 | 12 | 8 | 4 | 8 | mm |
| RGB6009 | 6 | 12.5 | 8.5 | 4 | 8 | mm |
| RGB6010 | 6.2 | 13 | 9 | 5 | 9 | mm |
| RGB6011 | 6.5 | 13.5 | 9.5 | 5 | 9 | mm |
| RGB6012 | 7 | 14 | 10 | 5 | 9 | mm |
| RGB6013 | 7.5 | 14.5 | 10.5 | 5 | 9 | mm |
| RGB6014 | 8 | 15 | 11 | 5 | 9 | mm |
| RGB6015 | 8.5 | 15.5 | 11.5 | 5 | 9 | mm |
39 BGA sizes with a closed central membrane. Match dimensions A through E to the section drawing and the panel opening.
| P/N | A | B | C | D | E | Unit |
|---|---|---|---|---|---|---|
| BGA1001 | 10 | 12 | 17 | 2.5 | 7.5 | mm |
| BGA1002 | 14 | 16 | 21 | 2.5 | 9.5 | mm |
| BGA1003 | 15 | 20 | 26 | 2 | 9 | mm |
| BGA1004 | 18 | 22 | 28 | 2.5 | 9.5 | mm |
| BGA1005 | 20 | 25 | 33 | 2.5 | 11 | mm |
| BGA1006 | 22 | 27 | 34 | 1.6 | 9 | mm |
| BGA1007 | 22 | 28 | 34 | 2.5 | 10 | mm |
| BGA1008 | 25 | 30 | 40 | 3 | 10 | mm |
| BGA1009 | 24 | 32 | 40 | 2.5 | 11 | mm |
| BGA1010 | 30 | 35 | 45 | 2.5 | 10 | mm |
| BGA1011 | 30 | 38 | 45 | 3 | 12 | mm |
| BGA1012 | 32 | 40 | 47 | 3 | 10.5 | mm |
| BGA1013 | 35 | 42 | 50 | 2.5 | 10.5 | mm |
| BGA1014 | 36 | 47 | 53 | 3 | 10 | mm |
| BGA1015 | 42 | 48 | 58 | 6 | 16 | mm |
Can't find the right size? Contact us for custom dimensions tailored to your requirements.
Identify key dimensions, mating surfaces and quantity
Agree the compound and manufacturing approach
Review the fit and agreed requirements in the assembly
Manufacture and check against the approved requirements
Identify temperature, contact fluids and repeated movement.
Consider hardness together with wall thickness and support.
Check access, mating dimensions and the fitting sequence.
Yes. Show the receiving opening, contact surfaces and clearance limits. We can review the dimensions and retaining features around the intended fit.
Agree the critical dimensions, material, hardness, visible surfaces and sample requirements. Explain how the part is installed and which interfaces control its function.
A sample can help explain the structure. Compare it with the assembly because wear, swelling or compression may have changed its original dimensions.
The material, part geometry, tooling, quantity and finishing affect the quotation. Include the intended batch size and delivery destination when describing your requirements.
DISCUSS THIS COMPONENT
Share the fit, operating conditions and quantity with our manufacturing team.