Working conditions
Identify temperature, contact fluids and repeated movement.

Custom manufacturing example · Custom molded nitrile rubber grommet silicone small grommets
CUSTOM RUBBER & SILICONE MANUFACTURING
A custom component for your assembly.
Define the mating surfaces, dimensions and working conditions. ETOL manufactures the part to the agreed design and material.
Share the part, its application and your estimated quantity.

Selected for the contact, temperature and movement
Define the visible surfaces and intended color
Develop holes, lips and walls around the mating parts
Match the attachment and installation method
A nitrile rubber grommet should use a selected NBR formulation suited to the actual cable contact and environment. Silicone variants may be developed for different conditions, but visually similar small parts should not be treated as interchangeable. The material choice and installed fit need assessment together.
Custom dimensions, hardness and colors allow the part to follow the opening. Define the cable bore and panel groove separately, including the finished jacket or wrapping that occupies the passage. The opening should provide enough space for the retaining lip to seat on both faces.
Evaluate representative assemblies with the intended material and cable. Check insertion, cable movement and panel retention after the route is secured. During maintenance, inspect for changes in surface condition or fit after exposure. Keep compound variants identified when their dimensions are the same. If the operating fluid or temperature changes, review the formulation rather than selecting a replacement only by size. A tighter fit should not be used as a substitute for a material suitable for the application.
Photos illustrate structure or material only. The opening should provide enough space for the retaining lip to seat on both faces. ETOL directly manufactures custom-shaped silicone and rubber parts to your requirements.
FIND THE RIGHT FIT
Choose a profile to compare part numbers and dimensions. Inch and metric sizes are listed in separate tables.
274 entries for Type D round through-hole grommets. Original fractions are retained, and exactly equivalent standard inch fractions replace decimal values where possible. Other values remain decimal inches.
| P/N | ID (C) | GD (A) | OD (D) | GW (B) | T (E) | Unit |
|---|---|---|---|---|---|---|
| RG2001 | 7/64 | 5/32 | 1/4 | 3/32 | 11/64 | inch |
| RG2002 | 7/64 | 5/32 | 1/4 | 3/64 | 11/64 | inch |
| RG2003 | 5/32 | 7/32 | 9/32 | 3/32 | 7/32 | inch |
| RG2004 | 1/8 | 3/16 | 5/16 | 1/16 | 3/16 | inch |
| RG2005 | 9/64 | 1/4 | 5/16 | 5/64 | 1/4 | inch |
| RG2006 | 5/32 | 1/4 | 5/16 | 7/64 | 13/64 | inch |
| RG2007 | 1/8 | 3/16 | 11/32 | 1/16 | 7/32 | inch |
| RG2008 | 1/8 | 1/4 | 11/32 | 1/16 | 7/32 | inch |
| RG2009 | 1/8 | 1/4 | 11/32 | 3/32 | 1/4 | inch |
| RG2010 | 9/64 | 3/16 | 11/32 | 1/16 | 3/16 | inch |
| RG2011 | 3/16 | 9/32 | 13/32 | 3/32 | 5/16 | inch |
| RG2012 | 3/16 | 5/16 | 13/32 | 1/16 | 7/32 | inch |
| RG2013 | 3/16 | 9/32 | 7/16 | 3/32 | 7/32 | inch |
| RG2014 | 3/16 | 5/16 | 7/16 | 1/16 | 3/16 | inch |
| RG2015 | 3/16 | 5/16 | 7/16 | 1/4 | 3/8 | inch |
866 entries for round panel openings. Compare the outside diameter, inside diameter, panel hole, panel thickness and overall thickness for the required fit.
| P/N | OD | ID | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RG6-2-4-1 | 6 | 2 | 4 | 1 | 3 | mm |
| RG6-2-4-1.5 | 6 | 2 | 4 | 1.5 | 3.5 | mm |
| RG6-2-4-2 | 6 | 2 | 4 | 2 | 4 | mm |
| RG8-2-6-1 | 8 | 2 | 6 | 1 | 3.4 | mm |
| RG8-2-6-1.5 | 8 | 2 | 6 | 1.5 | 3.9 | mm |
| RG8-2-6-2 | 8 | 2 | 6 | 2 | 4.4 | mm |
| RG8-3-6-1 | 8 | 3 | 6 | 1 | 3.4 | mm |
| RG8-3-6-1.5 | 8 | 3 | 6 | 1.5 | 3.9 | mm |
| RG8-3-6-2 | 8 | 3 | 6 | 2 | 4.4 | mm |
| RG8-4-6-1 | 8 | 4 | 6 | 1 | 3.4 | mm |
| RG8-4-6-1.5 | 8 | 4 | 6 | 1.5 | 3.9 | mm |
| RG8-4-6-2 | 8 | 4 | 6 | 2 | 4.4 | mm |
| RG10-3-7-1 | 10 | 3 | 7 | 1 | 4 | mm |
| RG10-3-7-1.5 | 10 | 3 | 7 | 1.5 | 4.5 | mm |
| RG10-3-7-2 | 10 | 3 | 7 | 2 | 5 | mm |
98 GRA sizes with a flanged sleeve profile. Compare the inside diameter, groove diameter and sleeve dimensions.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| GRA5000 | 2 | 8 | 5 | 7 | 8.5 | mm |
| GRA5001 | 3 | 8 | 5 | 7 | 8.5 | mm |
| GRA5002 | 3.5 | 9 | 6 | 8 | 9.5 | mm |
| GRA5003 | 3.2 | 8.2 | 6 | 8 | 9 | mm |
| GRA5004 | 3.5 | 11 | 6.8 | 8 | 10 | mm |
| GRA5005 | 4 | 10 | 7 | 8 | 9.5 | mm |
| GRA5006 | 4 | 11.5 | 7.3 | 8 | 10 | mm |
| GRA5007 | 4.5 | 12 | 7.8 | 8 | 10 | mm |
| GRA5008 | 4.5 | 11 | 8 | 8 | 9.5 | mm |
| GRA5009 | 5.5 | 13 | 9 | 8 | 10 | mm |
| GRA5010 | 5 | 12.5 | 8.3 | 8 | 10 | mm |
| GRA5011 | 5 | 13 | 9 | 9 | 11 | mm |
| GRA5012 | 6 | 14 | 10 | 9 | 11 | mm |
| GRA5013 | 7 | 15 | 11 | 10 | 12 | mm |
| GRA5014 | 7.5 | 16 | 12 | 10 | 12 | mm |
47 RGB sizes with a retaining lip below the mounting groove. Check the groove width and overall thickness for the panel assembly.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RGB6001 | 2 | 8.5 | 4.6 | 3 | 8 | mm |
| RGB6002 | 2.5 | 9 | 5 | 3 | 7 | mm |
| RGB6003 | 3 | 9.5 | 5.5 | 3 | 7 | mm |
| RGB6004 | 3.5 | 10 | 6 | 4 | 8 | mm |
| RGB6005 | 4 | 10.5 | 6.5 | 4 | 8 | mm |
| RGB6006 | 4.5 | 11 | 7 | 4 | 8 | mm |
| RGB6007 | 5 | 11.5 | 7.5 | 4 | 8 | mm |
| RGB6008 | 5.5 | 12 | 8 | 4 | 8 | mm |
| RGB6009 | 6 | 12.5 | 8.5 | 4 | 8 | mm |
| RGB6010 | 6.2 | 13 | 9 | 5 | 9 | mm |
| RGB6011 | 6.5 | 13.5 | 9.5 | 5 | 9 | mm |
| RGB6012 | 7 | 14 | 10 | 5 | 9 | mm |
| RGB6013 | 7.5 | 14.5 | 10.5 | 5 | 9 | mm |
| RGB6014 | 8 | 15 | 11 | 5 | 9 | mm |
| RGB6015 | 8.5 | 15.5 | 11.5 | 5 | 9 | mm |
39 BGA sizes with a closed central membrane. Match dimensions A through E to the section drawing and the panel opening.
| P/N | A | B | C | D | E | Unit |
|---|---|---|---|---|---|---|
| BGA1001 | 10 | 12 | 17 | 2.5 | 7.5 | mm |
| BGA1002 | 14 | 16 | 21 | 2.5 | 9.5 | mm |
| BGA1003 | 15 | 20 | 26 | 2 | 9 | mm |
| BGA1004 | 18 | 22 | 28 | 2.5 | 9.5 | mm |
| BGA1005 | 20 | 25 | 33 | 2.5 | 11 | mm |
| BGA1006 | 22 | 27 | 34 | 1.6 | 9 | mm |
| BGA1007 | 22 | 28 | 34 | 2.5 | 10 | mm |
| BGA1008 | 25 | 30 | 40 | 3 | 10 | mm |
| BGA1009 | 24 | 32 | 40 | 2.5 | 11 | mm |
| BGA1010 | 30 | 35 | 45 | 2.5 | 10 | mm |
| BGA1011 | 30 | 38 | 45 | 3 | 12 | mm |
| BGA1012 | 32 | 40 | 47 | 3 | 10.5 | mm |
| BGA1013 | 35 | 42 | 50 | 2.5 | 10.5 | mm |
| BGA1014 | 36 | 47 | 53 | 3 | 10 | mm |
| BGA1015 | 42 | 48 | 58 | 6 | 16 | mm |
Can't find the right size? Contact us for custom dimensions tailored to your requirements.
Identify key dimensions, mating surfaces and quantity
Agree the compound and manufacturing approach
Review the fit and agreed requirements in the assembly
Manufacture and check against the approved requirements
Identify temperature, contact fluids and repeated movement.
Consider hardness together with wall thickness and support.
Check access, mating dimensions and the fitting sequence.
Yes. Show the receiving opening, contact surfaces and clearance limits. We can review the dimensions and retaining features around the intended fit.
Agree the critical dimensions, material, hardness, visible surfaces and sample requirements. Explain how the part is installed and which interfaces control its function.
A sample can help explain the structure. Compare it with the assembly because wear, swelling or compression may have changed its original dimensions.
The material, part geometry, tooling, quantity and finishing affect the quotation. Include the intended batch size and delivery destination when describing your requirements.
DISCUSS THIS COMPONENT