Working conditions
Identify temperature, contact fluids and repeated movement.

Custom manufacturing example · Custom insulated rubber gasket/rubber wire harness grommets
CUSTOM RUBBER & SILICONE MANUFACTURING
A custom component for your assembly.
Define the mating surfaces, dimensions and working conditions. ETOL manufactures the part to the agreed design and material.
Share the part, its application and your estimated quantity.

Selected for the contact, temperature and movement
Define the visible surfaces and intended color
Develop holes, lips and walls around the mating parts
Match the attachment and installation method
Custom rubber wire harness grommets locate a rubber interface between wiring and a panel opening. Their mechanical purpose is to keep the harness jacket away from the edge while the retaining profile engages the panel. Any required electrical insulation must be addressed through the selected compound and the complete equipment design.
The contact at the hole should be continuous where the route needs protection. A folded retaining lip or a groove mismatched to the panel thickness can leave part of the edge exposed. Establish the finished cutout and harness dimensions, then inspect the interface after the bundle is secured in its final position.
Do not use the grommet to compensate for a harness route that is pulled too tightly across the panel. The intended clips or supports should carry that routing demand. Choose the material for the local exposure, including maintenance fluids, and keep grit from being trapped against the jacket. During replacement, preserve the bore and retaining geometry as well as the compound, since the visible flange alone does not define the fitted protection.
Photos illustrate structure or material only. A folded retaining lip or a groove mismatched to the panel thickness can leave part of the edge exposed. ETOL directly manufactures custom-shaped silicone and rubber parts to your requirements.
FIND THE RIGHT FIT
Choose a profile to compare part numbers and dimensions. Inch and metric sizes are listed in separate tables.
274 entries for Type D round through-hole grommets. Original fractions are retained, and exactly equivalent standard inch fractions replace decimal values where possible. Other values remain decimal inches.
| P/N | ID (C) | GD (A) | OD (D) | GW (B) | T (E) | Unit |
|---|---|---|---|---|---|---|
| RG2001 | 7/64 | 5/32 | 1/4 | 3/32 | 11/64 | inch |
| RG2002 | 7/64 | 5/32 | 1/4 | 3/64 | 11/64 | inch |
| RG2003 | 5/32 | 7/32 | 9/32 | 3/32 | 7/32 | inch |
| RG2004 | 1/8 | 3/16 | 5/16 | 1/16 | 3/16 | inch |
| RG2005 | 9/64 | 1/4 | 5/16 | 5/64 | 1/4 | inch |
| RG2006 | 5/32 | 1/4 | 5/16 | 7/64 | 13/64 | inch |
| RG2007 | 1/8 | 3/16 | 11/32 | 1/16 | 7/32 | inch |
| RG2008 | 1/8 | 1/4 | 11/32 | 1/16 | 7/32 | inch |
| RG2009 | 1/8 | 1/4 | 11/32 | 3/32 | 1/4 | inch |
| RG2010 | 9/64 | 3/16 | 11/32 | 1/16 | 3/16 | inch |
| RG2011 | 3/16 | 9/32 | 13/32 | 3/32 | 5/16 | inch |
| RG2012 | 3/16 | 5/16 | 13/32 | 1/16 | 7/32 | inch |
| RG2013 | 3/16 | 9/32 | 7/16 | 3/32 | 7/32 | inch |
| RG2014 | 3/16 | 5/16 | 7/16 | 1/16 | 3/16 | inch |
| RG2015 | 3/16 | 5/16 | 7/16 | 1/4 | 3/8 | inch |
866 entries for round panel openings. Compare the outside diameter, inside diameter, panel hole, panel thickness and overall thickness for the required fit.
| P/N | OD | ID | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RG6-2-4-1 | 6 | 2 | 4 | 1 | 3 | mm |
| RG6-2-4-1.5 | 6 | 2 | 4 | 1.5 | 3.5 | mm |
| RG6-2-4-2 | 6 | 2 | 4 | 2 | 4 | mm |
| RG8-2-6-1 | 8 | 2 | 6 | 1 | 3.4 | mm |
| RG8-2-6-1.5 | 8 | 2 | 6 | 1.5 | 3.9 | mm |
| RG8-2-6-2 | 8 | 2 | 6 | 2 | 4.4 | mm |
| RG8-3-6-1 | 8 | 3 | 6 | 1 | 3.4 | mm |
| RG8-3-6-1.5 | 8 | 3 | 6 | 1.5 | 3.9 | mm |
| RG8-3-6-2 | 8 | 3 | 6 | 2 | 4.4 | mm |
| RG8-4-6-1 | 8 | 4 | 6 | 1 | 3.4 | mm |
| RG8-4-6-1.5 | 8 | 4 | 6 | 1.5 | 3.9 | mm |
| RG8-4-6-2 | 8 | 4 | 6 | 2 | 4.4 | mm |
| RG10-3-7-1 | 10 | 3 | 7 | 1 | 4 | mm |
| RG10-3-7-1.5 | 10 | 3 | 7 | 1.5 | 4.5 | mm |
| RG10-3-7-2 | 10 | 3 | 7 | 2 | 5 | mm |
98 GRA sizes with a flanged sleeve profile. Compare the inside diameter, groove diameter and sleeve dimensions.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| GRA5000 | 2 | 8 | 5 | 7 | 8.5 | mm |
| GRA5001 | 3 | 8 | 5 | 7 | 8.5 | mm |
| GRA5002 | 3.5 | 9 | 6 | 8 | 9.5 | mm |
| GRA5003 | 3.2 | 8.2 | 6 | 8 | 9 | mm |
| GRA5004 | 3.5 | 11 | 6.8 | 8 | 10 | mm |
| GRA5005 | 4 | 10 | 7 | 8 | 9.5 | mm |
| GRA5006 | 4 | 11.5 | 7.3 | 8 | 10 | mm |
| GRA5007 | 4.5 | 12 | 7.8 | 8 | 10 | mm |
| GRA5008 | 4.5 | 11 | 8 | 8 | 9.5 | mm |
| GRA5009 | 5.5 | 13 | 9 | 8 | 10 | mm |
| GRA5010 | 5 | 12.5 | 8.3 | 8 | 10 | mm |
| GRA5011 | 5 | 13 | 9 | 9 | 11 | mm |
| GRA5012 | 6 | 14 | 10 | 9 | 11 | mm |
| GRA5013 | 7 | 15 | 11 | 10 | 12 | mm |
| GRA5014 | 7.5 | 16 | 12 | 10 | 12 | mm |
47 RGB sizes with a retaining lip below the mounting groove. Check the groove width and overall thickness for the panel assembly.
| P/N | ID | OD | GD | GW | T | Unit |
|---|---|---|---|---|---|---|
| RGB6001 | 2 | 8.5 | 4.6 | 3 | 8 | mm |
| RGB6002 | 2.5 | 9 | 5 | 3 | 7 | mm |
| RGB6003 | 3 | 9.5 | 5.5 | 3 | 7 | mm |
| RGB6004 | 3.5 | 10 | 6 | 4 | 8 | mm |
| RGB6005 | 4 | 10.5 | 6.5 | 4 | 8 | mm |
| RGB6006 | 4.5 | 11 | 7 | 4 | 8 | mm |
| RGB6007 | 5 | 11.5 | 7.5 | 4 | 8 | mm |
| RGB6008 | 5.5 | 12 | 8 | 4 | 8 | mm |
| RGB6009 | 6 | 12.5 | 8.5 | 4 | 8 | mm |
| RGB6010 | 6.2 | 13 | 9 | 5 | 9 | mm |
| RGB6011 | 6.5 | 13.5 | 9.5 | 5 | 9 | mm |
| RGB6012 | 7 | 14 | 10 | 5 | 9 | mm |
| RGB6013 | 7.5 | 14.5 | 10.5 | 5 | 9 | mm |
| RGB6014 | 8 | 15 | 11 | 5 | 9 | mm |
| RGB6015 | 8.5 | 15.5 | 11.5 | 5 | 9 | mm |
39 BGA sizes with a closed central membrane. Match dimensions A through E to the section drawing and the panel opening.
| P/N | A | B | C | D | E | Unit |
|---|---|---|---|---|---|---|
| BGA1001 | 10 | 12 | 17 | 2.5 | 7.5 | mm |
| BGA1002 | 14 | 16 | 21 | 2.5 | 9.5 | mm |
| BGA1003 | 15 | 20 | 26 | 2 | 9 | mm |
| BGA1004 | 18 | 22 | 28 | 2.5 | 9.5 | mm |
| BGA1005 | 20 | 25 | 33 | 2.5 | 11 | mm |
| BGA1006 | 22 | 27 | 34 | 1.6 | 9 | mm |
| BGA1007 | 22 | 28 | 34 | 2.5 | 10 | mm |
| BGA1008 | 25 | 30 | 40 | 3 | 10 | mm |
| BGA1009 | 24 | 32 | 40 | 2.5 | 11 | mm |
| BGA1010 | 30 | 35 | 45 | 2.5 | 10 | mm |
| BGA1011 | 30 | 38 | 45 | 3 | 12 | mm |
| BGA1012 | 32 | 40 | 47 | 3 | 10.5 | mm |
| BGA1013 | 35 | 42 | 50 | 2.5 | 10.5 | mm |
| BGA1014 | 36 | 47 | 53 | 3 | 10 | mm |
| BGA1015 | 42 | 48 | 58 | 6 | 16 | mm |
Can't find the right size? Contact us for custom dimensions tailored to your requirements.
Identify key dimensions, mating surfaces and quantity
Agree the compound and manufacturing approach
Review the fit and agreed requirements in the assembly
Manufacture and check against the approved requirements
Identify temperature, contact fluids and repeated movement.
Consider hardness together with wall thickness and support.
Check access, mating dimensions and the fitting sequence.
Yes. Show the receiving opening, contact surfaces and clearance limits. We can review the dimensions and retaining features around the intended fit.
Agree the critical dimensions, material, hardness, visible surfaces and sample requirements. Explain how the part is installed and which interfaces control its function.
A sample can help explain the structure. Compare it with the assembly because wear, swelling or compression may have changed its original dimensions.
The material, part geometry, tooling, quantity and finishing affect the quotation. Include the intended batch size and delivery destination when describing your requirements.